* feat: now when research is unlocked in console, approver of reasearch is radio-ed too
* refactor: now most of events that require actor name to be radio-ed or logged use TryGetIdentityShortInfoEvent which is subscibed by id-card system and borg system (to work for both carbon and synthetic life-forms)
* refactor: moved TryGetIdentityShortInfoEvent on id card system to shared, fixed cargo cent-com-originated orders
* remove unused check
* refactor: decoupled systems from IdCardSystem (those that are not dependent on it anymore)
* refactor: removed unuseed usings
* feat: emagged cargo/research consoles wont radio messages on buy/research confirm anymore
---------
Co-authored-by: pa.pecherskij <pa.pecherskij@interfax.ru>
* add tooltips to agentid job icons
* forgot to stage this
* make StatusIconPrototype abstract
* minor visual improvements
* cleanup
* use currentculture to sort job names
* review
* add LoggingDisabled to AccessReader
* add LogWireAction
* -m give everything besides high-security door a log wire
* make LogAccess public and support string arg
* add log when pulsing
* m
* l
---------
Co-authored-by: deltanedas <@deltanedas:kde.org>
* THE syndie microwave
* Always burn to explode microwave when copying
* Make it so copying ids stop when the microwave is goign to explode
* Made explosion destroy the board and spit out the machine parts
* Move logic is MicrowaveSystem, make metal cooking use the same logic
* Fix passing the wrong malfunction time
* Shuttle cannot escape aggressive branding
* Always make it explode with an id
* Forgot to invert bool, move it after fry chance
* Move job info changing methods for id cards to shared
* Revert "Move job info changing methods for id cards to shared"
This reverts commit 95cbc46b2d1934fa7bf5c72d7d3de9f9168992a1.
* Reapply changes
* Add door electronics configuration menu
* Use file-scoped namespaces
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Open door electronics configuration menu only with network configurator
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Doors will now try to move their AccessReaderComponent to their door electronics when the map is initialized
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Make the access list in the id card computer a separate control
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Fix merge conflict
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Remove DoorElectronics tag
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Integrate doors with #17927
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Move door electornics ui stuff to the right place
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Some review fixes
Signed-off-by: c4llv07e <kseandi@gmail.com>
* More fixes
Signed-off-by: c4llv07e <kseandi@gmail.com>
* review fix
Signed-off-by: c4llv07e <kseandi@gmail.com>
* move all accesses from airlock prototypes to door electronics
Signed-off-by: c4llv07e <kseandi@gmail.com>
* rework door electronics config access list
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Remove Linq from the door electronics user interface
* [WIP] Add EntityWhitelist to the activatable ui component
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Better interaction system
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Refactor
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Fix some door electronics not working without AccessReaderComponent
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Move AccessReaderComponent update code to the AccessReaderSystem
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Remove unnecesary newlines in the door access prototypes
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Remove unused variables in access level control
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Remove unnecessary method from the door electronics configuration menu
Signed-off-by: c4llv07e <kseandi@gmail.com>
* [WIP] change access type from string to ProtoId<AccessLevelPrototype>
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Remove unused methods
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Newline fix
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Restored to a functional state
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Fix access configurator not working with door electronics AccessReaderComponent
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Replace all string access fields with ProtoId
Signed-off-by: c4llv07e <kseandi@gmail.com>
* move access level control initialization into Populate method
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Review
---------
Signed-off-by: c4llv07e <kseandi@gmail.com>
Co-authored-by: metalgearsloth <comedian_vs_clown@hotmail.com>
* Merge BreakOnWeightlessMove and BreakOnMove. Provide different theshold for weightless movement.
* Adjust WeightlessMovementThresholds. Put a thing I forgot to put in the doafterargs.
* Make DoAfterArgs only use OnMove to determine whether to check for
movement and MoveThreshold to determine the threshold regardless of
weightlessness. Gave DistanceThreshold a default value which will always
be checked now.
* Fix issue introduced by merge.
* Use interaction system for determining whether a distance is within range
* Fix incorrect doafter args introduced by previous merge.
Forgor to commit these.
* Exorcise ghost.
The execution system should have been deleted when I merged previously.
For a reason I cannot comprehend it came back, but only the execution
system.
* Exorcise ghost Pt. 2
* Allow for movement check to be overriden in zero g and adjust doafter args where needed.
You can now override checking for movement in zero g with the BreakOnWeightlessMove bool. By default it will check.
The following doafters were made to ignore the movement check in zero g:
- Healing yourself with healing items,
- Removing embedded projectiles,
- Using tools like welders and crowbars
* Adjust distance for cuffing/uncuffing to work. Make injections not break on weightless movement.
* Fix evil incorrect and uneeded comments
* Use new Subs.CVar helper
Removes manual config OnValueChanged calls, removes need to remember to manually unsubscribe.
This both reduces boilerplate and fixes many issues where subscriptions weren't removed on entity system shutdown.
* Fix a bunch of warnings
* More warning fixes
* Use new DateTime serializer to get rid of ISerializationHooks in changelog code.
* Get rid of some more ISerializationHooks for enums
* And a little more
* Apply suggestions from code review
Co-authored-by: 0x6273 <0x40@keemail.me>
---------
Co-authored-by: 0x6273 <0x40@keemail.me>
* Fix ActivatableUIRequiresPowerCellComponent stopping power draw when one of two people closes the UI.
Also fixes it to check UiKey properly.
* Remove unnecessary CrewManifestViewer on PDAs
This is for a pop-up crew manifest UI, which the PDA doesn't use.
* Fix BoundUIClosedEvents that didn't check UI key/not correctly at least.
Uses the new helper method in engine.
* Fix drone (cargo shuttle) pilot console UI breaking if two people open it and one person closes it.
* Fixes for disposal router/tagger UI.
Code was badly copy pasted without changing identifiers, never worked.
Also cleaned up some of the logic (text trimming, sounds).
Also removed the "refuse to work if you have something in your active hand" check like why.
* Avoid running most ActivatableUIComponent logic when closing a UI via toggle
Activating the UI while it's already open closes it via toggle. Except it still ran 99% of the "attempting to open" logic which makes no sense.
This probably fixes a bug or some other dumb behavior somewhere.
* Bitch
The access configurator programs the access levels of any access reader. To use the access configurator, players must:
- Insert an ID card
- Click a nearby entity with an access reader with the access configurator in hand
- Change the access list
Note that players only need one of the access levels listed on the device to lock/unlock it, but will only be able to alter access settings when they all of the access levels listed on the device
For example, an airlock which has 'Science' and 'Engineering' access listed can be opened by any player with either 'Science' or 'Engineering' access. However, to change the access settings on this airlock, a player must have both 'Science' and 'Engineering' access. This is to prevent people from easily breaking into secure areas with this tool, by adding one of their own access levels to the target device
Obviously, the most useful ID card to use with this tool is one with all access, since it can change the settings of any device. Removing all access requirements from a device will make it useable by anyone.
---------
Co-authored-by: Kevin Zheng <kevinz5000@gmail.com>