Files
tbd-station-14/Resources/ServerInfo/Guidebook/Engineering/DeltaPressure.xml
ArtisticRoomba a93f6b8cdf Atmos dP Guidebook Entry (#40194)
* Add Atmos dP guidebook

* Update Resources/ServerInfo/Guidebook/Engineering/DeltaPressure.xml

---------

Co-authored-by: slarticodefast <161409025+slarticodefast@users.noreply.github.com>
2025-09-07 17:10:39 +02:00

70 lines
3.9 KiB
XML

<Document>
# Delta Pressure
Delta Pressure, or ΔP, is the difference in pressure between two areas.
This difference in pressure can exert a force on objects between the two areas, dealing [bold]pressure damage[/bold] to some objects in its way.
Various objects made out of glass, such as Windows, Windoors, and Shutters can experience pressure damage if the ΔP between the two sides is high enough.
This damage can cause these objects to shatter, allowing gas to flow freely between the two areas.
Different types of objects have different thresholds for how much ΔP they can withstand before shattering.
Generally, the stronger the glass, the higher the threshold. Objects that are thin will also have lower thresholds.
Objects like walls, airlocks, and firelocks are not affected by ΔP.
## Standard Glass and Objects
<Box>
<GuideEntityEmbed Entity="Window" Caption=""/>
<GuideEntityEmbed Entity="WindowDirectional" Caption=""/>
<GuideEntityEmbed Entity="Windoor" Caption=""/>
<GuideEntityEmbed Entity="ShuttersWindow" Caption=""/>
<GuideEntityEmbed Entity="InflatableWall" Caption=""/>
</Box>
Standard full-size glass and other weak objects can withstand a ΔP of up to [color=orange][protodata="Window" comp="DeltaPressure" member="MinPressureDelta"/] kPa[/color] before starting to crack.
Quarter-size glass, such as directional windows, can withstand a ΔP of up to [color=orange][protodata="WindowDirectional" comp="DeltaPressure" member="MinPressureDelta"/] kPa[/color] before starting to crack.
## Reinforced Glass and Objects
<Box>
<GuideEntityEmbed Entity="ReinforcedWindow" Caption=""/>
<GuideEntityEmbed Entity="WindowReinforcedDirectional" Caption=""/>
<GuideEntityEmbed Entity="WindoorSecure" Caption=""/>
<GuideEntityEmbed Entity="ShuttleWindow" Caption=""/>
</Box>
Reinforced full-size glass can withstand a ΔP of up to [color=orange][protodata="ReinforcedWindow" comp="DeltaPressure" member="MinPressureDelta"/] kPa[/color] before starting to crack.
Reinforced quarter-size glass can withstand a ΔP of up to [color=orange][protodata="WindowReinforcedDirectional" comp="DeltaPressure" member="MinPressureDelta"/] kPa[/color] before starting to crack.
## Plasma/Uranium Glass
<Box>
<GuideEntityEmbed Entity="PlasmaWindow" Caption=""/>
<GuideEntityEmbed Entity="PlasmaWindowDirectional" Caption=""/>
<GuideEntityEmbed Entity="WindoorPlasma" Caption=""/>
<GuideEntityEmbed Entity="UraniumWindow" Caption=""/>
<GuideEntityEmbed Entity="UraniumWindowDirectional" Caption=""/>
<GuideEntityEmbed Entity="WindoorUranium" Caption=""/>
</Box>
Plasma glass and uranium glass can withstand a ΔP of up to [color=orange][protodata="PlasmaWindow" comp="DeltaPressure" member="MinPressureDelta"/] kPa[/color] before starting to crack.
Plasma and uranium quarter-size glass can withstand a ΔP of up to [color=orange][protodata="PlasmaWindowDirectional" comp="DeltaPressure" member="MinPressureDelta"/] kPa[/color] before starting to crack.
## Reinforced Plasma/Uranium Glass
<Box>
<GuideEntityEmbed Entity="ReinforcedPlasmaWindow" Caption=""/>
<GuideEntityEmbed Entity="PlasmaReinforcedWindowDirectional" Caption=""/>
<GuideEntityEmbed Entity="WindoorSecurePlasma" Caption=""/>
<GuideEntityEmbed Entity="ReinforcedUraniumWindow" Caption=""/>
<GuideEntityEmbed Entity="UraniumReinforcedWindowDirectional" Caption=""/>
<GuideEntityEmbed Entity="WindoorSecureUranium" Caption=""/>
</Box>
Reinforced plasma glass and uranium glass can withstand a ΔP of up to [color=orange][protodata="ReinforcedPlasmaWindow" comp="DeltaPressure" member="MinPressureDelta"/] kPa[/color] before starting to crack.
Reinforced plasma and uranium quarter-size glass can withstand a ΔP of up to [color=orange][protodata="PlasmaReinforcedWindowDirectional" comp="DeltaPressure" member="MinPressureDelta"/] kPa[/color] before starting to crack.
</Document>