* Basic TEG start. Connects via node group. * Basic TEG test map * Sensor monitoring basics, TEG circulator flow * Basic power generation (it doesn't work) * More sensor monitoring work * Battery (SMES) monitoring system. * Sensor monitoring fixes Make it work properly when mapped. * Test map improvements * Revise TEG power output mechanism. Now uses a fixed supplier with a custom ramping system. * TEG test map fixes * Make air alarms and pumps open UI on activate. * Clean up thermo machines power switch. Removed separate Enabled bool from the component that always matched the power receiver's state. This enables adding a PowerSwitch component to give us alt click/verb menu. * TEG but now fancy * Make sensor monitoring console obviously WiP to mappers. * Vending machine sound, because of course. * Terrible, terrible graph background color * Examine improvements for the TEG. * Account for electrical power when equalizing gas mixtures. * Get rid of the TegCirculatorArrow logic. Use TimedDespawn instead. The "no show in right-click menuu" goes into a new general-purpose component. Thanks Julian. * Put big notice of "not ready, here's why" on the sensor monitoring console. * TryGetComponent -> TryComp * Lol there's a HideContextMenu tag * Test fixes * Guidebook for TEG Fixed rotation on GuideEntityEmbed not working correctly. Added Margin property to GuideEntityEmbed * Make TEG power bar default to invisible. So it doesn't appear in the guidebook and spawn menu.
48 lines
1.6 KiB
C#
48 lines
1.6 KiB
C#
using Content.Shared.Atmos;
|
|
|
|
namespace Content.Server.Atmos.Piping.Binary.Components
|
|
{
|
|
[RegisterComponent]
|
|
public sealed class GasVolumePumpComponent : Component
|
|
{
|
|
[ViewVariables(VVAccess.ReadWrite)]
|
|
[DataField("enabled")]
|
|
public bool Enabled { get; set; } = true;
|
|
|
|
[ViewVariables(VVAccess.ReadWrite)]
|
|
public bool Overclocked { get; set; } = false;
|
|
|
|
[ViewVariables(VVAccess.ReadWrite)]
|
|
[DataField("inlet")]
|
|
public string InletName { get; set; } = "inlet";
|
|
|
|
[ViewVariables(VVAccess.ReadWrite)]
|
|
[DataField("outlet")]
|
|
public string OutletName { get; set; } = "outlet";
|
|
|
|
[ViewVariables(VVAccess.ReadWrite)]
|
|
[DataField("transferRate")]
|
|
public float TransferRate { get; set; } = Atmospherics.MaxTransferRate;
|
|
|
|
[ViewVariables(VVAccess.ReadWrite)]
|
|
[DataField("maxTransferRate")]
|
|
public float MaxTransferRate { get; set; } = Atmospherics.MaxTransferRate;
|
|
|
|
[DataField("leakRatio")]
|
|
public float LeakRatio { get; set; } = 0.1f;
|
|
|
|
[DataField("lowerThreshold")]
|
|
public float LowerThreshold { get; set; } = 0.01f;
|
|
|
|
[DataField("higherThreshold")]
|
|
public float HigherThreshold { get; set; } = DefaultHigherThreshold;
|
|
public static readonly float DefaultHigherThreshold = 2 * Atmospherics.MaxOutputPressure;
|
|
|
|
[DataField("overclockThreshold")]
|
|
public float OverclockThreshold { get; set; } = 1000;
|
|
|
|
[DataField("lastMolesTransferred")]
|
|
public float LastMolesTransferred;
|
|
}
|
|
}
|