using Content.Shared.Atmos.Monitor.Components;
using Content.Shared.Atmos.Piping.Unary.Components;
using Robust.Client.AutoGenerated;
using Robust.Client.UserInterface.Controls;
using Robust.Client.UserInterface.XAML;
namespace Content.Client.Atmos.Monitor.UI.Widgets;
[GenerateTypedNameReferences]
public sealed partial class PumpControl : BoxContainer
{
private GasVentPumpData _data;
private string _address;
public event Action<string, IAtmosDeviceData>? PumpDataChanged;
public event Action<IAtmosDeviceData>? PumpDataCopied;
private CheckBox _enabled => CEnableDevice;
private CollapsibleHeading _addressLabel => CAddress;
private OptionButton _pumpDirection => CPumpDirection;
private OptionButton _pressureCheck => CPressureCheck;
private FloatSpinBox _externalBound => CExternalBound;
private FloatSpinBox _internalBound => CInternalBound;
private Button _copySettings => CCopySettings;
public PumpControl(GasVentPumpData data, string address)
{
RobustXamlLoader.Load(this);
Name = address;
_data = data;
_address = address;
_addressLabel.Title = Loc.GetString("air-alarm-ui-atmos-net-device-label", ("address", $"{address}"));
_enabled.Pressed = data.Enabled;
_enabled.OnToggled += _ =>
{
_data.Enabled = _enabled.Pressed;
PumpDataChanged?.Invoke(_address, _data);
};
_internalBound.Value = _data.InternalPressureBound;
_internalBound.OnValueChanged += _ =>
{
_data.InternalPressureBound = _internalBound.Value;
PumpDataChanged?.Invoke(_address, _data);
};
_internalBound.IsValid += value => value >= 0;
_externalBound.Value = _data.ExternalPressureBound;
_externalBound.OnValueChanged += _ =>
{
_data.ExternalPressureBound = _externalBound.Value;
PumpDataChanged?.Invoke(_address, _data);
};
_externalBound.IsValid += value => value >= 0;
foreach (var value in Enum.GetValues<VentPumpDirection>())
{
_pumpDirection.AddItem(Loc.GetString($"{value}"), (int) value);
}
_pumpDirection.SelectId((int) _data.PumpDirection);
_pumpDirection.OnItemSelected += args =>
{
_pumpDirection.SelectId(args.Id);
_data.PumpDirection = (VentPumpDirection) args.Id;
PumpDataChanged?.Invoke(_address, _data);
};
foreach (var value in Enum.GetValues<VentPressureBound>())
{
_pressureCheck.AddItem(Loc.GetString($"{value}"), (int) value);
}
_pressureCheck.SelectId((int) _data.PressureChecks);
_pressureCheck.OnItemSelected += args =>
{
_pressureCheck.SelectId(args.Id);
_data.PressureChecks = (VentPressureBound) args.Id;
PumpDataChanged?.Invoke(_address, _data);
};
_copySettings.OnPressed += _ =>
{
PumpDataCopied?.Invoke(_data);
};
}
public void ChangeData(GasVentPumpData data)
{
_data.Enabled = data.Enabled;
_enabled.Pressed = _data.Enabled;
_data.PumpDirection = data.PumpDirection;
_pumpDirection.SelectId((int) _data.PumpDirection);
_data.PressureChecks = data.PressureChecks;
_pressureCheck.SelectId((int) _data.PressureChecks);
_data.ExternalPressureBound = data.ExternalPressureBound;
_externalBound.Value = _data.ExternalPressureBound;
_data.InternalPressureBound = data.InternalPressureBound;
_internalBound.Value = _data.InternalPressureBound;
}
}