tbd-station-14/Content.Client/Atmos/Consoles/AtmosAlarmEntryContainer.xaml.cs
chromiumboy 27e59d35fb Atmospheric network monitor (#32294)
* Updated to latest master version

* Added gas pipe analyzer

* Completed prototype

* Playing with UI display

* Refinement of the main UI

* Renamed gas pipe analyzer to gas pipe sensor

* Added focus network highlighting and map icons for gas pipe sensors

* Added construction graph for gas pipe sensor

* Improved efficiency of atmos pipe and focus pipe network data storage

* Added gas pipe sensor variants

* Fixed gas pipe sensor nav map icon not highlighting on focus

* Rendered pipe lines now get merged together

* Set up appearance handling for the gas pipe sensor, but setting the layers is bugged

* Gas pipe sensor lights turn off when the device is unpowered

* Renamed console

* The gas pipe sensor is now a pipe. Redistributed components between it and its assembly

* AtmosMonitors can now optionally monitor their internal pipe network instead of the surrounding atmosphere

* Massive code clean up

* Added delta states to handle pipe net updates, fixed entity deletion handling

* Nav map blip data has been replaced with prototypes

* Nav map blip fixes

* Nav map colors are now set by the console component

* Made the nav map more responsive to changes in focus

* Updated nav map icons

* Reverted unnecessary namespace changes

* Code tidy up

* Updated sprites and construction graph for gas pipe sensor

* Updated localization files

* Misc bug fixes

* Added missing comment

* Fixed issue with the circuit board for the monitor

* Embellished the background of the console network entries

* Updated console to account for PR #32273

* Removed gas pipe sensor

* Fixing merge conflict

* Update

* Addressing reviews part 1

* Addressing review part 2

* Addressing reviews part 3

* Removed unnecessary references

* Side panel values will be grayed out if there is no gas present in the pipe network

* Declaring colors at the start of some files

* Added a colored stripe to the side of the atmos network entries

* Fixed an issue with pipe sensor blip coloration

* Fixed delay that occurs when toggling gas sensors on/off
2024-12-17 04:53:17 +01:00

201 lines
8.0 KiB
C#

using Content.Client.Stylesheets;
using Content.Shared.Atmos;
using Content.Shared.Atmos.Components;
using Content.Shared.Atmos.Monitor;
using Content.Shared.FixedPoint;
using Content.Shared.Temperature;
using Robust.Client.AutoGenerated;
using Robust.Client.Graphics;
using Robust.Client.ResourceManagement;
using Robust.Client.UserInterface.Controls;
using Robust.Client.UserInterface.XAML;
using Robust.Shared.Map;
using System.Linq;
namespace Content.Client.Atmos.Consoles;
[GenerateTypedNameReferences]
public sealed partial class AtmosAlarmEntryContainer : BoxContainer
{
public NetEntity NetEntity;
public EntityCoordinates? Coordinates;
private readonly IEntityManager _entManager;
private readonly IResourceCache _cache;
private Dictionary<AtmosAlarmType, string> _alarmStrings = new Dictionary<AtmosAlarmType, string>()
{
[AtmosAlarmType.Invalid] = "atmos-alerts-window-invalid-state",
[AtmosAlarmType.Normal] = "atmos-alerts-window-normal-state",
[AtmosAlarmType.Warning] = "atmos-alerts-window-warning-state",
[AtmosAlarmType.Danger] = "atmos-alerts-window-danger-state",
};
public AtmosAlarmEntryContainer(NetEntity uid, EntityCoordinates? coordinates)
{
RobustXamlLoader.Load(this);
_entManager = IoCManager.Resolve<IEntityManager>();
_cache = IoCManager.Resolve<IResourceCache>();
NetEntity = uid;
Coordinates = coordinates;
// Load fonts
var headerFont = new VectorFont(_cache.GetResource<FontResource>("/Fonts/NotoSans/NotoSans-Bold.ttf"), 11);
var normalFont = new VectorFont(_cache.GetResource<FontResource>("/Fonts/NotoSansDisplay/NotoSansDisplay-Regular.ttf"), 11);
var smallFont = new VectorFont(_cache.GetResource<FontResource>("/Fonts/NotoSans/NotoSans-Regular.ttf"), 10);
// Set fonts
TemperatureHeaderLabel.FontOverride = headerFont;
PressureHeaderLabel.FontOverride = headerFont;
OxygenationHeaderLabel.FontOverride = headerFont;
GasesHeaderLabel.FontOverride = headerFont;
TemperatureLabel.FontOverride = normalFont;
PressureLabel.FontOverride = normalFont;
OxygenationLabel.FontOverride = normalFont;
NoDataLabel.FontOverride = headerFont;
SilenceCheckBox.Label.FontOverride = smallFont;
SilenceCheckBox.Label.FontColorOverride = Color.DarkGray;
}
public void UpdateEntry(AtmosAlertsComputerEntry entry, bool isFocus, AtmosAlertsFocusDeviceData? focusData = null)
{
NetEntity = entry.NetEntity;
Coordinates = _entManager.GetCoordinates(entry.Coordinates);
// Load fonts
var normalFont = new VectorFont(_cache.GetResource<FontResource>("/Fonts/NotoSansDisplay/NotoSansDisplay-Regular.ttf"), 11);
// Update alarm state
if (!_alarmStrings.TryGetValue(entry.AlarmState, out var alarmString))
alarmString = "atmos-alerts-window-invalid-state";
AlarmStateLabel.Text = Loc.GetString(alarmString);
AlarmStateLabel.FontColorOverride = GetAlarmStateColor(entry.AlarmState);
// Update alarm name
AlarmNameLabel.Text = Loc.GetString("atmos-alerts-window-alarm-label", ("name", entry.EntityName), ("address", entry.Address));
// Focus updates
FocusContainer.Visible = isFocus;
if (isFocus)
SetAsFocus();
else
RemoveAsFocus();
if (isFocus && entry.Group == AtmosAlertsComputerGroup.AirAlarm)
{
MainDataContainer.Visible = (entry.AlarmState != AtmosAlarmType.Invalid);
NoDataLabel.Visible = (entry.AlarmState == AtmosAlarmType.Invalid);
if (focusData != null)
{
// Update temperature
var tempK = (FixedPoint2)focusData.Value.TemperatureData.Item1;
var tempC = (FixedPoint2)TemperatureHelpers.KelvinToCelsius(tempK.Float());
TemperatureLabel.Text = Loc.GetString("atmos-alerts-window-temperature-value", ("valueInC", tempC), ("valueInK", tempK));
TemperatureLabel.FontColorOverride = GetAlarmStateColor(focusData.Value.TemperatureData.Item2);
// Update pressure
PressureLabel.Text = Loc.GetString("atmos-alerts-window-pressure-value", ("value", (FixedPoint2)focusData.Value.PressureData.Item1));
PressureLabel.FontColorOverride = GetAlarmStateColor(focusData.Value.PressureData.Item2);
// Update oxygenation
var oxygenPercent = (FixedPoint2)0f;
var oxygenAlert = AtmosAlarmType.Invalid;
if (focusData.Value.GasData.TryGetValue(Gas.Oxygen, out var oxygenData))
{
oxygenPercent = oxygenData.Item2 * 100f;
oxygenAlert = oxygenData.Item3;
}
OxygenationLabel.Text = Loc.GetString("atmos-alerts-window-oxygenation-value", ("value", oxygenPercent));
OxygenationLabel.FontColorOverride = GetAlarmStateColor(oxygenAlert);
// Update other present gases
GasGridContainer.RemoveAllChildren();
var gasData = focusData.Value.GasData.Where(g => g.Key != Gas.Oxygen);
var keyValuePairs = gasData.ToList();
if (keyValuePairs.Count == 0)
{
// No other gases
var gasLabel = new Label()
{
Text = Loc.GetString("atmos-alerts-window-other-gases-value-nil"),
FontOverride = normalFont,
FontColorOverride = StyleNano.DisabledFore,
HorizontalAlignment = HAlignment.Center,
VerticalAlignment = VAlignment.Center,
HorizontalExpand = true,
Margin = new Thickness(0, 2, 0, 0),
SetHeight = 24f,
};
GasGridContainer.AddChild(gasLabel);
}
else
{
// Add an entry for each gas
foreach ((var gas, (var mol, var percent, var alert)) in keyValuePairs)
{
FixedPoint2 gasPercent = percent * 100f;
var gasAbbreviation = Atmospherics.GasAbbreviations.GetValueOrDefault(gas, Loc.GetString("gas-unknown-abbreviation"));
var gasLabel = new Label()
{
Text = Loc.GetString("atmos-alerts-window-other-gases-value", ("shorthand", gasAbbreviation), ("value", gasPercent)),
FontOverride = normalFont,
FontColorOverride = GetAlarmStateColor(alert),
HorizontalAlignment = HAlignment.Center,
VerticalAlignment = VAlignment.Center,
HorizontalExpand = true,
Margin = new Thickness(0, 2, 0, 0),
SetHeight = 24f,
};
GasGridContainer.AddChild(gasLabel);
}
}
}
}
}
public void SetAsFocus()
{
FocusButton.AddStyleClass(StyleNano.StyleClassButtonColorGreen);
ArrowTexture.TexturePath = "/Textures/Interface/Nano/inverted_triangle.svg.png";
}
public void RemoveAsFocus()
{
FocusButton.RemoveStyleClass(StyleNano.StyleClassButtonColorGreen);
ArrowTexture.TexturePath = "/Textures/Interface/Nano/triangle_right.png";
FocusContainer.Visible = false;
}
private Color GetAlarmStateColor(AtmosAlarmType alarmType)
{
switch (alarmType)
{
case AtmosAlarmType.Normal:
return StyleNano.GoodGreenFore;
case AtmosAlarmType.Warning:
return StyleNano.ConcerningOrangeFore;
case AtmosAlarmType.Danger:
return StyleNano.DangerousRedFore;
}
return StyleNano.DisabledFore;
}
}