* Add door electronics configuration menu * Use file-scoped namespaces Signed-off-by: c4llv07e <kseandi@gmail.com> * Open door electronics configuration menu only with network configurator Signed-off-by: c4llv07e <kseandi@gmail.com> * Doors will now try to move their AccessReaderComponent to their door electronics when the map is initialized Signed-off-by: c4llv07e <kseandi@gmail.com> * Make the access list in the id card computer a separate control Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix merge conflict Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove DoorElectronics tag Signed-off-by: c4llv07e <kseandi@gmail.com> * Integrate doors with #17927 Signed-off-by: c4llv07e <kseandi@gmail.com> * Move door electornics ui stuff to the right place Signed-off-by: c4llv07e <kseandi@gmail.com> * Some review fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * More fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * review fix Signed-off-by: c4llv07e <kseandi@gmail.com> * move all accesses from airlock prototypes to door electronics Signed-off-by: c4llv07e <kseandi@gmail.com> * rework door electronics config access list Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove Linq from the door electronics user interface * [WIP] Add EntityWhitelist to the activatable ui component Signed-off-by: c4llv07e <kseandi@gmail.com> * Better interaction system Signed-off-by: c4llv07e <kseandi@gmail.com> * Refactor Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix some door electronics not working without AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Move AccessReaderComponent update code to the AccessReaderSystem Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecesary newlines in the door access prototypes Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused variables in access level control Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecessary method from the door electronics configuration menu Signed-off-by: c4llv07e <kseandi@gmail.com> * [WIP] change access type from string to ProtoId<AccessLevelPrototype> Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused methods Signed-off-by: c4llv07e <kseandi@gmail.com> * Newline fix Signed-off-by: c4llv07e <kseandi@gmail.com> * Restored to a functional state Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix access configurator not working with door electronics AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Replace all string access fields with ProtoId Signed-off-by: c4llv07e <kseandi@gmail.com> * move access level control initialization into Populate method Signed-off-by: c4llv07e <kseandi@gmail.com> * Review --------- Signed-off-by: c4llv07e <kseandi@gmail.com> Co-authored-by: metalgearsloth <comedian_vs_clown@hotmail.com>
43 lines
1.1 KiB
C#
43 lines
1.1 KiB
C#
using Robust.Shared.GameStates;
|
|
using Robust.Shared.Serialization;
|
|
using Robust.Shared.Prototypes;
|
|
using Content.Shared.Access;
|
|
|
|
namespace Content.Shared.Doors.Electronics;
|
|
|
|
/// <summary>
|
|
/// Allows an entity's AccessReader to be configured via UI.
|
|
/// </summary>
|
|
[RegisterComponent, NetworkedComponent]
|
|
public sealed partial class DoorElectronicsComponent : Component
|
|
{
|
|
}
|
|
|
|
[Serializable, NetSerializable]
|
|
public sealed class DoorElectronicsUpdateConfigurationMessage : BoundUserInterfaceMessage
|
|
{
|
|
public List<ProtoId<AccessLevelPrototype>> AccessList;
|
|
|
|
public DoorElectronicsUpdateConfigurationMessage(List<ProtoId<AccessLevelPrototype>> accessList)
|
|
{
|
|
AccessList = accessList;
|
|
}
|
|
}
|
|
|
|
[Serializable, NetSerializable]
|
|
public sealed class DoorElectronicsConfigurationState : BoundUserInterfaceState
|
|
{
|
|
public List<ProtoId<AccessLevelPrototype>> AccessList;
|
|
|
|
public DoorElectronicsConfigurationState(List<ProtoId<AccessLevelPrototype>> accessList)
|
|
{
|
|
AccessList = accessList;
|
|
}
|
|
}
|
|
|
|
[Serializable, NetSerializable]
|
|
public enum DoorElectronicsConfigurationUiKey : byte
|
|
{
|
|
Key
|
|
}
|