Better plasma and tritium fires (#22468)
This commit is contained in:
@@ -179,11 +179,11 @@ namespace Content.Shared.Atmos
|
||||
/// <summary>
|
||||
/// Amount of heat released per mole of burnt hydrogen or tritium (hydrogen isotope)
|
||||
/// </summary>
|
||||
public const float FireHydrogenEnergyReleased = 560000f;
|
||||
public const float FireHydrogenEnergyReleased = 284e3f; // hydrogen is 284 kJ/mol
|
||||
public const float FireMinimumTemperatureToExist = T0C + 100f;
|
||||
public const float FireMinimumTemperatureToSpread = T0C + 150f;
|
||||
public const float FireSpreadRadiosityScale = 0.85f;
|
||||
public const float FirePlasmaEnergyReleased = 3000000f;
|
||||
public const float FirePlasmaEnergyReleased = 16e3f; // methane is 16 kJ/mol
|
||||
public const float FireGrowthRate = 40000f;
|
||||
|
||||
public const float SuperSaturationThreshold = 96f;
|
||||
@@ -216,7 +216,7 @@ namespace Content.Shared.Atmos
|
||||
/// Remove X mol of nitrogen for each mol of frezon.
|
||||
/// </summary>
|
||||
public const float FrezonNitrogenCoolRatio = 5;
|
||||
public const float FrezonCoolEnergyReleased = -3000000f;
|
||||
public const float FrezonCoolEnergyReleased = -600e3f;
|
||||
public const float FrezonCoolRateModifier = 20f;
|
||||
|
||||
public const float FrezonProductionMaxEfficiencyTemperature = 73.15f;
|
||||
|
||||
Reference in New Issue
Block a user