Unhardcode some logic related to objects with battery slots. Minor fix to fire helmets. (#11734)
This commit is contained in:
@@ -10,6 +10,7 @@ using Content.Shared.Rounding;
|
||||
using Robust.Shared.Containers;
|
||||
using System.Diagnostics.CodeAnalysis;
|
||||
using Content.Server.Kitchen.Components;
|
||||
using Content.Shared.Containers.ItemSlots;
|
||||
|
||||
namespace Content.Server.PowerCell;
|
||||
|
||||
@@ -17,8 +18,10 @@ public sealed class PowerCellSystem : SharedPowerCellSystem
|
||||
{
|
||||
[Dependency] private readonly SolutionContainerSystem _solutionsSystem = default!;
|
||||
[Dependency] private readonly ExplosionSystem _explosionSystem = default!;
|
||||
[Dependency] private readonly IAdminLogManager _adminLogger= default!;
|
||||
[Dependency] private readonly IAdminLogManager _adminLogger = default!;
|
||||
[Dependency] private readonly SharedContainerSystem _containerSystem = default!;
|
||||
[Dependency] private readonly ItemSlotsSystem _itemSlotsSystem = default!;
|
||||
[Dependency] private readonly SharedAppearanceSystem _sharedAppearanceSystem = default!;
|
||||
|
||||
public override void Initialize()
|
||||
{
|
||||
@@ -36,10 +39,13 @@ public sealed class PowerCellSystem : SharedPowerCellSystem
|
||||
|
||||
private void OnSlotMicrowaved(EntityUid uid, PowerCellSlotComponent component, BeingMicrowavedEvent args)
|
||||
{
|
||||
if (component.CellSlot.Item == null)
|
||||
return;
|
||||
if (_itemSlotsSystem.TryGetSlotById(uid, component.CellSlotId, out ItemSlot? slot))
|
||||
{
|
||||
if (slot.Item == null)
|
||||
return;
|
||||
|
||||
RaiseLocalEvent(component.CellSlot.Item.Value, args, false);
|
||||
RaiseLocalEvent(slot.Item.Value, args, false);
|
||||
}
|
||||
}
|
||||
|
||||
private void OnMicrowaved(EntityUid uid, BatteryComponent component, BeingMicrowavedEvent args)
|
||||
@@ -69,14 +75,15 @@ public sealed class PowerCellSystem : SharedPowerCellSystem
|
||||
|
||||
var frac = battery.CurrentCharge / battery.MaxCharge;
|
||||
var level = (byte) ContentHelpers.RoundToNearestLevels(frac, 1, PowerCellComponent.PowerCellVisualsLevels);
|
||||
appearance.SetData(PowerCellVisuals.ChargeLevel, level);
|
||||
_sharedAppearanceSystem.SetData(uid, PowerCellVisuals.ChargeLevel, level, appearance);
|
||||
|
||||
// If this power cell is inside a cell-slot, inform that entity that the power has changed (for updating visuals n such).
|
||||
if (_containerSystem.TryGetContainingContainer(uid, out var container)
|
||||
&& TryComp(container.Owner, out PowerCellSlotComponent? slot)
|
||||
&& slot.CellSlot.Item == uid)
|
||||
&& _itemSlotsSystem.TryGetSlotById(container.Owner, slot.CellSlotId, out ItemSlot? itemSlot))
|
||||
{
|
||||
RaiseLocalEvent(container.Owner, new PowerCellChangedEvent(false), false);
|
||||
if (itemSlot.Item == uid)
|
||||
RaiseLocalEvent(container.Owner, new PowerCellChangedEvent(false), false);
|
||||
}
|
||||
}
|
||||
|
||||
@@ -101,7 +108,13 @@ public sealed class PowerCellSystem : SharedPowerCellSystem
|
||||
return false;
|
||||
}
|
||||
|
||||
return TryComp(component.CellSlot.Item, out battery);
|
||||
if (_itemSlotsSystem.TryGetSlotById(uid, component.CellSlotId, out ItemSlot? slot))
|
||||
{
|
||||
return TryComp(slot.Item, out battery);
|
||||
}
|
||||
|
||||
battery = null;
|
||||
return false;
|
||||
}
|
||||
|
||||
private void OnSolutionChange(EntityUid uid, PowerCellComponent component, SolutionChangedEvent args)
|
||||
|
||||
Reference in New Issue