Adds the thermo-electric generator (#18840)
* Basic TEG start. Connects via node group. * Basic TEG test map * Sensor monitoring basics, TEG circulator flow * Basic power generation (it doesn't work) * More sensor monitoring work * Battery (SMES) monitoring system. * Sensor monitoring fixes Make it work properly when mapped. * Test map improvements * Revise TEG power output mechanism. Now uses a fixed supplier with a custom ramping system. * TEG test map fixes * Make air alarms and pumps open UI on activate. * Clean up thermo machines power switch. Removed separate Enabled bool from the component that always matched the power receiver's state. This enables adding a PowerSwitch component to give us alt click/verb menu. * TEG but now fancy * Make sensor monitoring console obviously WiP to mappers. * Vending machine sound, because of course. * Terrible, terrible graph background color * Examine improvements for the TEG. * Account for electrical power when equalizing gas mixtures. * Get rid of the TegCirculatorArrow logic. Use TimedDespawn instead. The "no show in right-click menuu" goes into a new general-purpose component. Thanks Julian. * Put big notice of "not ready, here's why" on the sensor monitoring console. * TryGetComponent -> TryComp * Lol there's a HideContextMenu tag * Test fixes * Guidebook for TEG Fixed rotation on GuideEntityEmbed not working correctly. Added Margin property to GuideEntityEmbed * Make TEG power bar default to invisible. So it doesn't appear in the guidebook and spawn menu.
This commit is contained in:
committed by
GitHub
parent
61bf951ec4
commit
a242af506e
@@ -11,10 +11,6 @@ namespace Content.Server.Atmos.Piping.Unary.Components
|
||||
[DataField("inlet")]
|
||||
public string InletName = "pipe";
|
||||
|
||||
[ViewVariables(VVAccess.ReadWrite)]
|
||||
[DataField("enabled")]
|
||||
public bool Enabled = false;
|
||||
|
||||
/// <summary>
|
||||
/// Current maximum temperature, calculated from <see cref="BaseHeatCapacity"/> and the quality of matter
|
||||
/// bins. The heat capacity effectively determines the rate at which the thermo machine can add or remove
|
||||
@@ -93,5 +89,11 @@ namespace Content.Server.Atmos.Piping.Unary.Components
|
||||
[DataField("machinePartTemperature", customTypeSerializer: typeof(PrototypeIdSerializer<MachinePartPrototype>))]
|
||||
public string MachinePartTemperature = "Capacitor";
|
||||
|
||||
/// <summary>
|
||||
/// Last amount of energy added/removed from the attached pipe network
|
||||
/// </summary>
|
||||
[DataField("lastEnergyDelta")]
|
||||
[ViewVariables(VVAccess.ReadWrite)]
|
||||
public float LastEnergyDelta;
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue