Add door electronics access configuration menu (#17778)
* Add door electronics configuration menu * Use file-scoped namespaces Signed-off-by: c4llv07e <kseandi@gmail.com> * Open door electronics configuration menu only with network configurator Signed-off-by: c4llv07e <kseandi@gmail.com> * Doors will now try to move their AccessReaderComponent to their door electronics when the map is initialized Signed-off-by: c4llv07e <kseandi@gmail.com> * Make the access list in the id card computer a separate control Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix merge conflict Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove DoorElectronics tag Signed-off-by: c4llv07e <kseandi@gmail.com> * Integrate doors with #17927 Signed-off-by: c4llv07e <kseandi@gmail.com> * Move door electornics ui stuff to the right place Signed-off-by: c4llv07e <kseandi@gmail.com> * Some review fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * More fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * review fix Signed-off-by: c4llv07e <kseandi@gmail.com> * move all accesses from airlock prototypes to door electronics Signed-off-by: c4llv07e <kseandi@gmail.com> * rework door electronics config access list Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove Linq from the door electronics user interface * [WIP] Add EntityWhitelist to the activatable ui component Signed-off-by: c4llv07e <kseandi@gmail.com> * Better interaction system Signed-off-by: c4llv07e <kseandi@gmail.com> * Refactor Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix some door electronics not working without AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Move AccessReaderComponent update code to the AccessReaderSystem Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecesary newlines in the door access prototypes Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused variables in access level control Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecessary method from the door electronics configuration menu Signed-off-by: c4llv07e <kseandi@gmail.com> * [WIP] change access type from string to ProtoId<AccessLevelPrototype> Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused methods Signed-off-by: c4llv07e <kseandi@gmail.com> * Newline fix Signed-off-by: c4llv07e <kseandi@gmail.com> * Restored to a functional state Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix access configurator not working with door electronics AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Replace all string access fields with ProtoId Signed-off-by: c4llv07e <kseandi@gmail.com> * move access level control initialization into Populate method Signed-off-by: c4llv07e <kseandi@gmail.com> * Review --------- Signed-off-by: c4llv07e <kseandi@gmail.com> Co-authored-by: metalgearsloth <comedian_vs_clown@hotmail.com>
This commit is contained in:
@@ -35,6 +35,7 @@ using Robust.Shared.Map.Components;
|
||||
using Robust.Shared.Physics;
|
||||
using Robust.Shared.Physics.Components;
|
||||
using Robust.Shared.Player;
|
||||
using Robust.Shared.Prototypes;
|
||||
using Robust.Shared.Utility;
|
||||
|
||||
namespace Content.Server.Administration.Systems;
|
||||
@@ -844,14 +845,14 @@ public sealed partial class AdminVerbSystem
|
||||
{
|
||||
var allAccess = _prototypeManager
|
||||
.EnumeratePrototypes<AccessLevelPrototype>()
|
||||
.Select(p => p.ID).ToArray();
|
||||
.Select(p => new ProtoId<AccessLevelPrototype>(p.ID)).ToArray();
|
||||
|
||||
_accessSystem.TrySetTags(entity, allAccess);
|
||||
}
|
||||
|
||||
private void RevokeAllAccess(EntityUid entity)
|
||||
{
|
||||
_accessSystem.TrySetTags(entity, Array.Empty<string>());
|
||||
_accessSystem.TrySetTags(entity, new List<ProtoId<AccessLevelPrototype>>());
|
||||
}
|
||||
|
||||
public enum TricksVerbPriorities
|
||||
|
||||
Reference in New Issue
Block a user